Description
FLIR CM57-2 Clamp Meter with Flexible Coil
The FLIR CM57-2 is a flexible clamp meter designed for difficult current measurements. With its 45.72 cm (18-inch) flexible coil clamp, the CM57-2 allows you to take measurements in tight spots, making it ideal for multiple-conductor measurements and double-wrap requirements.
The CM57-2 meter also features dual LED work lights for better visibility, and AC current ranges from 30.00 A to 3000 A. Stream live data in real time from the CM57-2 to your mobile device over Bluetooth using the METERLiNK® app to visually compare log files, customise alarm thresholds, create reports, and share readings instantly with team members.
TEST LEADS AND PROBES
- FLIR TA55 AC Current Line Splitter
CASES AND POUCHES
- FLIR TA17 Pouch for Clamp Meters
- FLIR TA10-F Protective Case for DM9x, and the TA72/74 Series
- FLIR TA15 Universal Soft Sided Case (TA15)
FLIR METERLiNK App
Get inspection information to the people you need the FLIR METERLiNK app. METERLiNK allows you to safely capture images and monitor hazardous areas remotely and in real time. You can monitor a variety of environmental and electrical conditions simultaneously with the ability to connect with up to seven FLIR compatible meters at once.
Whether you’re connecting several FLIR clamp meters, digital multimeters, or any of the new METERLiNK app compatible meters, you will be able to keep tabs on key readings around your facility and easily share them with your team.
FLIR CM57-2 Technical Specifications
MEASUREMENT & ANALYSIS | |
---|---|
AC Current Bandwidth | 45–500 Hz (sine wave) |
AC Current Ranges and Resolution | 30.00 A, 300.0 A, 3000 A |
AC Response | True RMS |
Basic AC current accuracy (of reading) | ±3.0% + 5 digits |
Display Rate | 2 times per second |
Flex Coil Length | 45 cm (18 in) |
Flex Coil Tip Diameter | 13 mm (0.5 in) |
Inrush Current | Minimum 0.5 A, 100 mS |
Max Conductor Diameter | 12 cm (4.7 in) |
Maximum AC current | 3000 A AC |
Maximum resolution | 0.01 A |
Measurement Rate | 1.5 samples per second, nominal |
Positional Error [distance from optimum] | 35 mm (1.4 in) ±1.0%, 50 mm (2.0 in) ±1.5%, 60 mm (2.4 in) ±2.0% |
COMMUNICATION & DATA STORAGE | |
Bluetooth range max | 10 m (32 ft) |
Data Record Mode | 20,000 points; 1 minute sample rate |
Wireless ID# max | Up to 20 |
USER INTERFACE | |
Display | 3000-count LCD with backlight and multi‐function indicators |
POWER | |
Auto Power Off | Approximately 10 minutes |
Battery Life | 100 hours with alkaline batteries (calculated) |
Battery Type | 2 x 1.5 V AAA |
GENERAL | |
Coil Bend Radius | 80 mm (3.1 in) |
Coil Diameter | 7.5 mm (0.3 in) |
Display Indications | Progressive low battery, over range, hold |
Maximum Conductor Diameter | 12 cm (4.7 in) |
Size [L × W × H] | 330 mm × 175 mm × 28.45 mm ( 13 in × 6.89 in × 1.12 in) |
Weight | 233 g (0.51 lb) with batteries |
Worklights | 2x LEDs |
ENVIRONMENTAL & CERTIFICATIONS | |
Certifications | UL, CE, FCC, IC, UKCA, CSAUS |
Drop test | 3 m (9.8 ft) |
IP Rating | IP54 dust-protected and splash-resistant |
Operating Altitude | 2000 m (6562 ft) max |
Operating Humidity | Maximum 80% up to 35°C (95°F) decreasing linearly to 60% at 45°C (113°F) |
Operating Temperature | 0°C to 50°C (32°F to 122°F) |
Safety Rating | CAT IV-600 V, CAT III-1000 V |
STANDARDS | |
Safety (UL) | IEC 61010-1:2010, IEC 61010-2-032:2012 |
EMC (FCC) | 47 CFR Part 15 Subpart B |
EMC (CE) | EN IEC 61326-1:2021 |
EN IEC 61326-2-2:2021 | |
EN 301 489-1 V2.2.3 (2019-11) | |
EN 301 489-17 V3.2.4 (2020-09) | |
RF | |
ETSI EN 300 328 V2.2.2 | |
EN 62479:2010 | |
EN 50663:2017 | |
TEMPERATURE | |
Storage Humidity | 80% relative humidity (maximum) |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) without batteries |
Temperature Coefficient | 0.2 × specified accuracy/°C, <64.5°F (18°C), >82.4°F (28°C) |